Skip to main content

Laboratory Feezer
FROSTER LABEX 530 ULTIMATE

Maximum safety down to -30°C in ATEX protection zone 2: With its elegant glass touchscreen, access control, efficient forced-air cooling, automatic defrosting and quick-freeze system, this laboratory freezer offers everything that modern laboratories need. The fused circulating air fan ensures maximum temperature precision, while the explosion protection (zone 2) guarantees maximum safety. In addition, the integrated door frame heater reliably prevents the door from freezing shut and enables easy and convenient use.

  • 5 grids
  • Explosion protection (zone 2) more information
  • Forced-air cooling
  • External dimensions 77 x 76 x 195.5 (W x D x H in cm)
  • Equipment

    According to DIN 13277

    Ensuring the correct storage of medicines requiring refrigeration in the healthcare sector To ensure this, there is the DIN 13277 standard for medicine refrigerators. This The standard specifies ten requirements that a medicine refrigerator must meet must be done to ensure the effectiveness of the stored medicine is preserved. Furthermore, the DIN standard is not only for correct storage, but also to protect the medicine against unauthorized access and the Compliance with occupational health and safety guidelines regarding protection against noise.

    Automatic defrost

    Thanks to a time-limited and thermally monitored inversion of the refrigerant circuit.

    Reduced energy consumption

    Most of our devices now have a refrigeration machine with inverter technology. Reduced energy consumption and longevity are at the heart of this innovative system. This reduces your operating costs and protects the environment. Thanks to the excellent temperature stability, your refrigerated products remain safely cooled at all times, even when the doors are opened and after defrosting. Benefit from quiet operation and low maintenance requirements.

    Cooling by air circulation

    Automatically turns off when the door is opened, provides uniform temperature control and reduces temperature gradient to a minimum.

    Trust the market leader

    World's lowest temperature deviations from the warmest to the coldest storage location thanks to PRO-ACTIVE control & KIRSCH air-guidance concept.

    Door frame heating

    prevents the door from freezing.

    Conformity
    • DIN EN ISO 9001
    • Explosion-proof interior in accordance with ATEX directive 2014/34/EU (more information)
    • DIN 13277
    KIRSCH aerial guidance concept
    • Minimal temperature differences between the warmest storage location and the coldest storage location thanks to PRO-ACTIVE monitoring and control. KIRSCH air traffic control concept
    • PRO-ACTIVE monitoring: continuous, proactive monitoring of performance data and alerting in the event of deviations
    • Precise temperature control thanks to two PT-1000 temperature sensors with safety barriers

    Concept of ergonomics
    • Flexible interior design
    • Ergonomic door opener
    • Automatic defrost
    • Height-adjustable grids
    • Heating the door frame prevents the door from freezing
    Security and digital documentation
    • Electronic door lock
    • Optical and acoustic alarm signal even in the event of a power failure
    • Minimum/maximum temperature memory
    • Potential-free contact for connection to remote warning systems
    • Digital data documentation via network (PC-KIT-NET) and KIRSCH Datanet software
    Ultimate Line
    • Simple operation thanks to capacitive glass touchscreen
    • Operation also possible with laboratory gloves
    • Operation via remote access possible (with network connection)
    • Access control with RFID and/or code with protocol and integrated user management
    • Alarm and status messages in plain text
    • Graphical display of temperature evolution
    • Quick commissioning
    • including the benefits of the PRO-ACTIVE range
  • Technical data

    Capacity 500 l
    Temperature setting (approx.) -10 to -30 °C
    Voltage 220 - 240 V
    Frequency 50 / 60 Hz
    Power consumption 550 Watts
    Average consumption 5.8 KWh / 24 h
    Overall dimensions (incl. distance from wall) 77 x 76 x 195,5 (w x d x h in cm)
    Interior dimensions 62 x 57 x 140 (w x d x h in cm)
    Overall dimensions with door
    opened at 90°
    77 x 144 (w x d in cm)
    Shelf dimensions 59 x 45 (w x d in cm)
    Max. loading capacity per shelf 40 kg
    Weight 141 kg / 164 kg (net / gross)
     
  • Downloads

    Product information

    Laboratory Freezer FROSTER LABEX® 530 ULTIMATE

    Info sheet explosion protection

    Operating instructions

    Operating instructions FROSTER LABEX® 530 ULTIMATE

    Additional instructions ULTIMATE

    Additional instructions PC-KIT-STICK

    Conformity statement

    The safety of our LABEX® models has been confirmed by means of the conformity statement issued by TÜV-SÜD.

    Conformity statement 

  • Videos

    Kirsch ULTIMATE Productline

     

    Kirsch Ergonomics-Concept

     

    Kirsch Reliability